Cooling Tower Services
for Institutional & Commercial Facilities in Southern California
24/7/365 cooling tower service and maintenance across Southern California — Title 24 compliant, water-conscious, and performance-driven.
Hospitals • Universities • Government & Defense • Labs & Biotech •
High‑rise Office • K‑12 Schools • Manufacturing & Food Processing •
Data Centers • Cultural & Public Assembly
Equipment We Service & Maintain
Cooling Tower Types: Crossflow • Counterflow • Induced Draft • Forced Draft • Natural Draft • Hybrid / Plume Abatement • Closed-Circuit (Fluid Cooler)
Marley® NC, Marley® MD, Marley® AV
Series 3000, PT2, FXV, CXVT
AT Atlas, ESWA, eco-ATWB Hybrid
TM Series, Paragon
Cooling Tower Services
Trusted Maintenance
Comprehensive cooling tower maintenance programs – available on quarterly, semi-annual, and annual schedules – designed for maximum reliability, efficiency, and compliance. Services include seasonal start-up and shutdown, basin and fill inspections, fan and motor service, belt and gearbox maintenance, vibration testing, and drift eliminator checks. We also support connected systems such as pumps and heat exchangers. Every visit includes detailed digital service reports, water treatment and compliance documentation, and asset condition assessments to support long-term capital planning.
Basin, fill, drift eliminator, fan, and motor inspections with vibration testing and alignment checks
Gearbox service, belt and bearing replacement, nozzle and distribution system cleaning
Upgrades for energy efficiency, plume abatement, noise reduction, and extended service life
Optimization & Retrofits
Performance-Focused Retrofits
Our approach to cooling tower optimization focuses on extending equipment life, reducing water and energy consumption, and meeting strict Southern California compliance requirements. We implement advanced strategies such as variable frequency drives on fans and pumps, automated basin heater controls, and ambient wet-bulb reset for condenser water. Additional retrofit options include high-efficiency fill media, low-drift eliminators, corrosion-resistant components, and plume abatement systems that address local water and air quality concerns.
Water & Energy Efficiency Benchmarking
Each project begins with clear performance benchmarking. We establish a baseline that includes fan power (kW), approach temperature, water usage, blowdown cycles, and drift loss. From there, adaptive fan sequencing and setpoint control are applied to balance performance with utility costs and water conservation mandates. Benchmarking data is validated against utility-grade trend reports, giving owners transparent before-and-after documentation of system improvements.
Monitoring & Reliability Assurance
Optimization doesn’t end with installation. Our monitoring framework provides real-time alerts for abnormal fan power draw, basin temperature fluctuations, water level issues, and vibration trends. Secure remote monitoring with automated notifications enables proactive service, while monthly performance reviews ensure towers operate at peak efficiency throughout seasonal changes. This ongoing assurance protects your investment, supports compliance with Title 24 and SCAQMD, and sustains long-term operational savings.
Why Facilities Choose Us
We deliver critical cooling tower solutions that safeguard uptime, extend equipment life, and meet California’s strict regulatory and water conservation requirements — all while reducing energy and maintenance costs.
End-to-End Support
From design and installation to start-up, preventative maintenance, retrofits, and emergency service — our team covers the full lifecycle of your cooling tower assets.
Regulatory Confidence
We manage projects to satisfy Title 24 (Part 6), CALGreen commissioning, and SCAQMD drift requirements, while coordinating permits, documentation, and health and safety compliance.
Emergency Readiness
24/7/365 dispatch with guaranteed response times for mission-critical facilities, helping prevent costly downtime and compliance risks.
Unified Responsibility
One dedicated team for towers, pumps, water treatment, and controls – ensuring seamless coordination, vendor management, and hands-on training for your staff.
Water & Energy Efficiency
Our optimization strategies reduce fan energy, minimize drift and blowdown, and improve water conservation, with trend data that proves measurable results.
Common Inquiries
FAQs
How often should a commercial cooling tower be serviced?
Cooling towers should be inspected and serviced at least quarterly, with monthly water treatment monitoring for most facilities. Preventive maintenance includes basin cleaning, fill inspection, drift eliminator checks, nozzle flushing, and fan/gearbox service. Regular attention prevents scale, corrosion, and Legionella risk while ensuring compliance with Title 24 and CALGreen performance standards.
Can cooling towers operate during maintenance or replacement?
In many cases, tower service can be staged to keep critical loads online. For multi-cell towers, one cell can remain operational while another undergoes cleaning or repairs. For single-cell systems, temporary rental towers or portable fluid coolers can be deployed to maintain uptime.
Does cooling tower maintenance reduce energy and water costs?
Yes. Clean fill media, efficient drift eliminators, balanced nozzles, and optimized fan control improve heat transfer while reducing fan kW and water blowdown. Proper water treatment also minimizes scale and biological fouling, extending equipment life and lowering operating costs.
Do you handle SCAQMD drift and emissions compliance?
Absolutely. We verify that drift eliminators meet SCAQMD standards (≤0.002% drift) and provide documentation to support regulatory inspections. Our services also align with Title 24, CALGreen, and ASHRAE guidelines to ensure environmental and health compliance.
Can cooling tower controls integrate with our BAS?
Yes. We provide controls integration for fan sequencing, water level sensors, conductivity monitoring, and vibration alerts. Integration with BACnet/IP, Modbus, and other protocols ensures your BAS has full visibility into tower performance.
Are there rebates or incentives for cooling tower upgrades?
Southern California utilities frequently offer incentives for VFD fan retrofits, high-efficiency fill replacement, and hybrid cooling solutions that reduce water consumption. We help facilities identify and capture available rebates to lower capital costs.
What are the signs my cooling tower needs repair or replacement?
Warning signs include visible corrosion, reduced water flow, scaling or fouling on fill, excessive vibration or noise, drift water escaping, and rising approach temperatures. Regular inspections catch issues early, but persistent performance loss may indicate the need for major repair or replacement.
How long do cooling towers typically last?
A well-maintained cooling tower can last 20–30 years. Service life depends on material type (galvanized steel, stainless steel, FRP, or HDPE), water chemistry, and maintenance practices. Corrosion, scaling, or neglected water treatment can shorten lifespan significantly.
Ready to talk? Schedule a site walk today.
OUR FEATURES
More flexible and helpful solutions for you and your clients needs.
%
reprehenderit qui in ea voluptate velit esse quam nihil vel illum qui.
Simple Video View
Dolor sit amet consectetur adipisci velit, sed quia non numquam eius modi tempora incidunt ut labore.
Uncompromised security
Natus sit voluptatem accusantium doloremque laudantium, totam rem aperiam, eaque ipsa quae ab illo veritatis.
Encourage Continuous improvements.
Perspiciatis unde omnis iste natus sit voluptatem accusantium doloremque laudantium totam rem aperiam eaque.